Product Details:
Payment & Shipping Terms:
|
Brand: | KRIPAL | Current Range: | 100A 125A 150 A 180A 220A |
---|---|---|---|
Poles: | 4P | Contacts: | Silver Ag |
Coil: | AC/DC | ||
Highlight: | Definite Purpose Contactor |
Power saving Air Conditioning Contactors 4 Pole AC Contactor 125A 150A
Description:
Magnetic AC Contactor should have the high current value without being exposed to and damaged or boiling. This belongs to the quality of contactor. (Contact surface quality and weld technology) Especially at AC-3 and capacitor command, selectivity of contactor is very important.
Current which passes through the contacts causes warming when the contactor is closed. This warming is limited with the standards. For IEC60947-4-1 when continual thermal current (Ith) is passed though the main contacts, maximum increasing temperature should not exceed 65k.
Characteristics:
1. 3 pairs of main contacts: 85% Ag
2. Enclsoure: fire- retardant
3. Button: resin (bearing temperature more thant 250 degree)
2. Fixed by screw
3. AC/DC coil
4. Wide coil voltage
5. Be connected with the thermal overload relay directly
Specifications:
Model |
UKC1-100 |
UKC1-125 |
UKC1-150 |
UKC1-180 |
UKC1-220 |
|
Rated operational current |
Ie max AC-3 |
105A |
125A |
150A |
180A |
220A |
Ie AC-1 |
150A |
150A |
200A |
230A |
260A |
|
Rated operational power in AC-3 |
220/240V |
30KW |
37KW |
45KW |
55KW |
75KW |
380/400V |
55KW |
60KW |
75KW |
90KW |
132KW |
|
415/440V |
55KW |
60KW |
75KW |
90KW |
132KW |
|
500V |
55KW |
60KW |
90KW |
110KW |
132KW |
|
660/690V |
55KW |
60KW |
90KW |
110KW |
132KW |
|
Thermal overload relays |
class 10A |
34...125A |
34...125A |
34...150A |
65…240A |
65…240A |
class 20A |
34...125A |
34...125A |
34...150A |
65…240A |
65…240A |
Special Features:
AC/DC contactor:
Contactor applications: remote making and breaking circuits
AC/DC contactor protects circuit from overloading when assembling thermal overload relay
Frequent start-up and control:
Contactor electric ratings: AC 50/60Hz, 690V, up to 95A
Utilization category: AC-3, AC-4
Altitude: ≤2000m
Ambient temperature: -5-40º C
Mounting category: III
Mounting conditions: inclination between mounting plane
Vertical plane should not exceed ±5°
Standards for AC contactor: IEC/EN 60947-4-1. IEC/EN 60947-5-1
Advantages:
1. Power saving: 5% of traditional power consuming.
2. Long life: short arc duration, little contactor ablation, contactor does not quiver when voltage fluctuates.
3. Reliable coils will not be burnt which are reeled in our own workshop
4. No noise during working
5. There is no temperature rising in the coil control.
6. Not influenced by network voltage fluctuation.
7. Plastic are fire-retardant and the button is resin which can bear temperature more than 200 degree Celsius
Special requirements?
Our project engineers are here to understand the special requirements of your project and assist to develop a solution as a partner.
Should your requirements not be covered by our extensive standard product range we have our own R&D and mould tooling center for special switches in order to flexibly, promptly and cost effectively meet your individual requirements.
Just let us know your ideas, and we will show you a great solution.
Contact Person: Mr. fov
Tel: 18810166789
Fax: 86-189-4289-0330
5 Years Warranty MN11-1 Mini Circuit Breaker With Soonest Delivery
6-32a Mini Circuit Breaker DPN Type MCB For Household Installation
Terminal 3P Mini Circuit Breaker For Pin / Fork Busbar Connection 6A 10A
22KA Moulded Case Residential Circuit Breaker , Miniature Circuit Breakers
Electrical Moulded Case Circuit Breakers Automotive , Commercial Circuit Breaker
MCCB Moulded Case 3 Pole Circuit Breakers Low Voltage , Industrial Circuit Breakers
Low Voltage 6A - 63A Residual Current Circuit Breaker With Compact Design
Residual Current Circuit Breaker With Own Design And Steady Market
Residual Current Circuit Breaker Low Voltage 6A - 63A With Compact Design