Product Details:
Payment & Shipping Terms:
|
Highlight: | High Performance Liquid Chromatographic |
---|
Features
Applications:
Medical and pharmaceuticals
Health and epidemic prevention
Environmental monitoring
Agriculture, forestry, fisheries, animal husbandry
Manufacturing
Petrochemical
Quality control
Education and scientific research
Water reservation system
Specifications:
LC210 Pump |
|
Type |
Serial dual plunger |
Flow range |
0.001-10.000ml/min, 0.001ml/min increment |
Compressive compensation |
User defined |
Seal wash |
Manual |
Max pressure |
40Mpa/5800psi |
Pressure ripple |
≤1% (1ml/min, degassed methol) |
Flow precision |
≤0.075%RSD |
Flow accuracy |
+1% |
Number of solvents and setting range |
Isocratic, 0-100%, 0.1 increments |
Composition accuracy |
≤2% |
Power requirements |
95-240V 150VA 50Hz |
Dimension |
392x550x169mm |
Weight |
14.5kg |
Sound pressure level |
<70dB |
|
|
LC220 UV Detector |
|
Lamp source |
Deuterium lamp, Tungsten lamp |
Wavelength range |
190-800nm |
Bandwidth |
6nm |
Wavelength accuracy |
+1nm |
Wavelength precision |
≤0.2nm |
Linear range |
>104 |
Noise |
+0.75x10-5AU (dry cell, 254nm, response time 1s) |
Drift |
1x10-4AU/h (dry cell, 24nm, responses time 1s) |
Detection limit |
≤5x10-9g/ml (naphthalene/methanol) |
Flow cell volume |
10μl |
Pressure limit |
10Mpa/1500psi |
Responses time |
0.1-2s |
Operating temperature range |
10-40℃ |
Power requirements |
95-240V 150VA 50Hz |
Dimension |
392x550x169mm |
Weight |
12kg |
Sound pressure level |
<70dB |
|
|
LC230 Auto Sampler |
|
Loop volume (100μl) |
1-5000μl programmable (10ml loop optional) |
Syringe volume |
500μl (2500μl optional) |
Sample capacity |
2x48 vial tray for 1.5ml vial (optional 12 position 10ml vial tray, 96 well plate formats, 384 well plate formats) |
Switching time of injection valve |
<100ms |
Piercing precision needle |
≤0.6mm |
Injection cycle time |
17s (60s while needle washing) |
Injection modes |
Full loop, partial loopfill and μl pickup mode |
Reproducibility |
Full loop < 0.3% Partial loopfill < 0.5% Μl pickup < 1% |
Carry over |
<0.05% |
Cooling (optional) |
4℃ to ambient-3℃ |
Power requirements |
95-240V 150VA 50Hz |
Dimension |
300x510x360mm, 300x575x360 with cooling |
Weight |
19kg; 21kg with cooling |
Sound pressure level |
<70dB |
|
|
LC240 Column Oven |
|
Model |
LC240 and LC242 LC241 and LC243 |
Temperature range |
Ambient - 100℃, 0.1 increment |
Temperature accuracy |
+5℃ |
Temperature stability |
≤0.1℃ |
Cooling (optional) |
Minimum to ambient - 15℃ |
Columns accommodated |
3 columns, 15-25cm |
|
|
LC250 Degasser |
|
Type |
LC250 membrane online degasser 2 channel LC251 membrane online degasser 3 channel LC252 membrane online degasser 4 channel |
Volume |
10ml/min |
Diode Array Detector 2600 |
|
Light source |
Deuterium |
Measurement range |
190-500nm |
Detection type |
Diode array, 1.25nm dot pitch, 256 diodes |
Bandwidth |
4-25nm, user selectable |
Wavelength accuracy |
≤1nm |
Wavelength validation |
Automatic via internal Holmium Oxide filter |
Noise |
≤1x10-5AU |
Drift |
≤5x10-5AU/hr |
Linearity |
0-1.5AU |
Measurement range |
0-2.2AU |
Spectra |
4 spectra can be stored |
Integration time range |
13-200ms |
Time constants |
0.1-10.0 second in 1-2-5 steps |
|
|
ELSD Detector Chromachem |
|
Light source |
High intensity Halogen lamp (multicolor) |
Detector |
Photomultiplier (high sensitivity) |
Analogue signal output |
0-1V |
Detect limit |
<10ng glucose (non-column injection) |
Heating time |
<10min heat up to 150℃ |
Temperature range |
Evaporation chamber: maximum 150℃, increase by 1℃ Nebulizer: maximum 70℃ |
Autozero |
Front panel or external trigger |
Nebulizer type |
Venture tube, temperature controllable |
Gas flow rate |
1-2l/min, recommended pressure 1-2bars |
Spectra |
4 spectra can be stored |
Integration time range |
13-200ms |
Time constants |
0.1-10.0 second in 1-2-5 steps |
|
|
Refractive Index Detector 201H |
|
Refractive index range |
1.00-1.75 |
Detection range |
0.25-512μRIU |
Linear range |
≥600μRIU |
Noise |
≤2.5nRIU (pure water, response time: 1.5second) |
Response time |
0.1, 0.25, 0.5, 1, 1.5, 2, 3, 6 second |
Autozero |
Automatic zero |
Autozero range |
Full range |
Deviation adjustable range |
10μRIU |
Detection cell volume |
8μl |
Flow rate |
Common value 0.2-3.0ml/min, maximum 10ml/min (pure water) |
Highest pressure |
0.05Mpa |
Dead volume |
670μl |
Temperature control |
Off, 30-50℃ (each time 1℃), 77℃ fuse (dual temperature control) |
|
|
Fluorescence Detector RF20Axs |
|
Light source |
Xenon lamp Low pressure Mercury (for wavelength accuracy correction) |
Wavelength range |
200-750nm |
Spectral bandwidth |
20nm |
Wavelength accuracy |
+2nm |
S/N |
Raman peak of water S/N above 2000 |
Detection cell temperature range |
4℃-40℃, 1℃ increment |
Detection cell temperature control range |
(ambient-10)℃-40℃ |
Detection cell |
Standard detection cell: volume: 12μl, withstanding pressure: 2Mpa Half-micro detection cell: volume: 12μl, withstanding pressure: 2Mpa |
Functions |
Simultaneous double-wavelength test, wavelength scanning |
Safety protection |
Leakage sensor |
Operation temperature range |
4℃-35℃ |
Contact Person: Mr. fov
Tel: 18810166789
Fax: 86-189-4289-0330
5 Years Warranty MN11-1 Mini Circuit Breaker With Soonest Delivery
6-32a Mini Circuit Breaker DPN Type MCB For Household Installation
Terminal 3P Mini Circuit Breaker For Pin / Fork Busbar Connection 6A 10A
22KA Moulded Case Residential Circuit Breaker , Miniature Circuit Breakers
Electrical Moulded Case Circuit Breakers Automotive , Commercial Circuit Breaker
MCCB Moulded Case 3 Pole Circuit Breakers Low Voltage , Industrial Circuit Breakers
Low Voltage 6A - 63A Residual Current Circuit Breaker With Compact Design
Residual Current Circuit Breaker With Own Design And Steady Market
Residual Current Circuit Breaker Low Voltage 6A - 63A With Compact Design