Home ProductsFlexible Membrane Switch

Reliability And Stability HPLC Model LC200 With Isocratic Or Gradient Pump

Certification
China Shenzhen City Breaker Co., Ltd. certification
China Shenzhen City Breaker Co., Ltd. certification
Excellent quality and fast delivery.

—— Victor

I want to say that your products very good. Thank you for all your suggestion, also good after sales service.

—— Mr Abílio Cipriano

Easy to talk with, very professional and fast service, the flag quality is super good. Even better than we ordered from Germany!!

—— Germany Fabian Scherb

I'm Online Chat Now

Reliability And Stability HPLC Model LC200 With Isocratic Or Gradient Pump

Reliability And Stability HPLC Model LC200 With Isocratic Or Gradient Pump
Reliability And Stability HPLC Model LC200 With Isocratic Or Gradient Pump Reliability And Stability HPLC Model LC200 With Isocratic Or Gradient Pump

Large Image :  Reliability And Stability HPLC Model LC200 With Isocratic Or Gradient Pump

Product Details:
Brand Name: PG instruments
Certification: CE
Model Number: LC200
Payment & Shipping Terms:
Minimum Order Quantity: 1 unit
Price: Contact for a quote
Packaging Details: Carton package
Delivery Time: Contact for confirmation
Payment Terms: T/T,L/C
Supply Ability: 400 units per year
Detailed Product Description
Highlight:

High Performance Liquid Chromatographic

Reliability And Stability HPLC Model LC200 With Isocratic Or Gradient Pump

 

 

Features

  • Accurate flow rate
  • Excellent reliability and stability
  • Full control via powerful LC Win software
  • Modular design enables flexible configurations
  • Automatic data save in the event of accidental power shortage



Applications:

Medical and pharmaceuticals
Health and epidemic prevention
Environmental monitoring
Agriculture, forestry, fisheries, animal husbandry
Manufacturing
Petrochemical
Quality control
Education and scientific research
Water reservation system

 

 

 

 

Specifications:

 

LC210 Pump

Type 

Serial dual plunger

Flow range

0.001-10.000ml/min, 0.001ml/min increment

Compressive compensation 

User defined 

Seal wash

Manual

Max pressure

40Mpa/5800psi

Pressure ripple

≤1% (1ml/min, degassed methol)

Flow precision

≤0.075%RSD

Flow accuracy

+1%

Number of solvents and setting range

Isocratic, 0-100%, 0.1 increments

Composition accuracy

≤2%

Power requirements

95-240V 150VA 50Hz

Dimension 

392x550x169mm

Weight 

14.5kg

Sound pressure level

<70dB

 

LC220 UV Detector 

Lamp source

Deuterium lamp, Tungsten lamp

Wavelength range

190-800nm

Bandwidth 

6nm

Wavelength accuracy

+1nm

Wavelength precision

≤0.2nm

Linear range

>104

Noise 

+0.75x10-5AU (dry cell, 254nm, response time 1s)

Drift 

1x10-4AU/h (dry cell, 24nm, responses time 1s)

Detection limit

≤5x10-9g/ml (naphthalene/methanol)

Flow cell volume

10μl

Pressure limit

10Mpa/1500psi

Responses time 

0.1-2s

Operating temperature range 

10-40℃

Power requirements

95-240V 150VA 50Hz

Dimension 

392x550x169mm

Weight 

12kg

Sound pressure level

<70dB

 

LC230 Auto Sampler

Loop volume (100μl)

1-5000μl programmable (10ml loop optional)

Syringe volume 

500μl (2500μl optional)

Sample capacity

2x48 vial tray for 1.5ml vial (optional 12 position 10ml vial tray, 

96 well plate formats, 384 well plate formats)

Switching time of injection valve

<100ms

Piercing precision needle

≤0.6mm

Injection cycle time

17s (60s while needle washing)

Injection modes

Full loop, partial loopfill and μl pickup mode

Reproducibility 

Full loop < 0.3%

Partial loopfill < 0.5%

Μl pickup < 1%

Carry over

<0.05%

Cooling (optional)

4℃ to ambient-3℃

Power requirements

95-240V 150VA 50Hz

Dimension 

300x510x360mm, 300x575x360 with cooling

Weight 

19kg; 21kg with cooling

Sound pressure level

<70dB

 

LC240 Column Oven

Model 

LC240 and LC242

LC241 and LC243

Temperature range

Ambient - 100℃, 0.1 increment 

Temperature accuracy 

+5℃

Temperature stability

≤0.1℃

Cooling (optional)

Minimum to ambient - 15℃

Columns accommodated 

3 columns, 15-25cm

 

LC250 Degasser

Type 

LC250 membrane online degasser 2 channel

LC251 membrane online degasser 3 channel

LC252 membrane online degasser 4 channel

Volume 

10ml/min

 

Diode Array Detector 2600

Light source 

Deuterium

Measurement range

190-500nm

Detection type 

Diode array, 1.25nm dot pitch, 256 diodes

Bandwidth 

4-25nm, user selectable

Wavelength accuracy

≤1nm

Wavelength validation

Automatic via internal Holmium Oxide filter

Noise 

≤1x10-5AU

Drift 

≤5x10-5AU/hr

Linearity 

0-1.5AU

Measurement range 

0-2.2AU

Spectra 

4 spectra can be stored

Integration time range

13-200ms

Time constants 

0.1-10.0 second in 1-2-5 steps

 

ELSD Detector Chromachem

Light source 

High intensity Halogen lamp (multicolor)

Detector 

Photomultiplier (high sensitivity)

Analogue signal output

0-1V

Detect limit

<10ng glucose (non-column injection)

Heating time

<10min heat up to 150℃

Temperature range

Evaporation chamber: maximum 150℃, 

increase by 1℃

Nebulizer: maximum 70℃

Autozero

Front panel or external trigger

Nebulizer type 

Venture tube, temperature controllable

Gas flow rate

1-2l/min, recommended pressure 1-2bars

Spectra

4 spectra can be stored

Integration time range

13-200ms

Time constants 

0.1-10.0 second in 1-2-5 steps

 

Refractive Index Detector 201H

Refractive index range

1.00-1.75

Detection range

0.25-512μRIU

Linear range

≥600μRIU

Noise 

≤2.5nRIU (pure water, response time: 1.5second)

Response time

0.1, 0.25, 0.5, 1, 1.5, 2, 3, 6 second

Autozero

Automatic zero

Autozero range

Full range

Deviation adjustable range

10μRIU

Detection cell volume

8μl

Flow rate

Common value 0.2-3.0ml/min, maximum 10ml/min (pure water)

Highest pressure

0.05Mpa

Dead volume

670μl

Temperature control

Off, 30-50℃ (each time 1℃), 77℃ fuse 

(dual temperature control)

 

Fluorescence Detector RF20Axs 

Light source

Xenon lamp Low pressure Mercury (for wavelength accuracy 

correction)

Wavelength range

200-750nm

Spectral bandwidth 

20nm

Wavelength accuracy

+2nm

S/N

Raman peak of water S/N above 2000

Detection cell temperature range

4℃-40℃, 1℃ increment

Detection cell temperature control range

(ambient-10)℃-40℃

Detection cell 

Standard detection cell: volume: 12μl, 

withstanding pressure: 2Mpa

Half-micro detection cell: volume: 12μl, 

withstanding pressure: 2Mpa

Functions 

Simultaneous double-wavelength test, wavelength scanning

Safety protection 

Leakage sensor

Operation temperature range 

4℃-35℃

 

 

 

Contact Details
Shenzhen City Breaker Co., Ltd.

Contact Person: Mr. fov

Tel: 18810166789

Fax: 86-189-4289-0330

Send your inquiry directly to us (0 / 3000)