Home ProductsMembrane Switch Panel

3-Phase Single Bearing John Deere Diesel Generator , 3029DF128

Certification
China Shenzhen City Breaker Co., Ltd. certification
China Shenzhen City Breaker Co., Ltd. certification
Excellent quality and fast delivery.

—— Victor

I want to say that your products very good. Thank you for all your suggestion, also good after sales service.

—— Mr Abílio Cipriano

Easy to talk with, very professional and fast service, the flag quality is super good. Even better than we ordered from Germany!!

—— Germany Fabian Scherb

I'm Online Chat Now

3-Phase Single Bearing John Deere Diesel Generator , 3029DF128

3-Phase Single Bearing John Deere Diesel Generator , 3029DF128
3-Phase Single Bearing John Deere Diesel Generator , 3029DF128

Large Image :  3-Phase Single Bearing John Deere Diesel Generator , 3029DF128

Product Details:
Place of Origin: China
Brand Name: JACKPOWER
Model Number: BCJD 22-50
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Price: Negotiable
Packaging Details: Standard plywood and wood package.the actual package size against genset size and handle requires.
Delivery Time: 5-6 weeks on receipt of official sales contract
Payment Terms: L/C,D/P,D/A, Alipay, West Union, TT. Cash,Paypal
Supply Ability: 20sets per Month.
Port:: HongKong or ShenZhen,ShangHai,Dalian as required
Detailed Product Description
High Light:

standby diesel generator

,

portable diesel powered generators

  1. Generater Model:BCJD 22-50
  2. Frequency:50 Hz
  3. Cooling Method:  Water
  4. Power Factor:0.8
  5. 3 phase
  6. Prime Power:19KVA/15KWe
  7. Standby Power : 21KVA/17KWe/28Amps

 

3-Phase Single Bearing Diesel Generator , 3029DF128

3-Phase Single Bearing John Deere Diesel Generator , 3029DF128 0

 

Definition of Ratings & Reference Conditions

Prime Power (PRP) is the nominal output continuously available, where the average load (variable) does not exceed 70% of the prime power rating. 10% overload is available for a maximum of 1 hour in 12 hours of operation.

Standby Power (LTP) is the maximum output available, for up to 500 hours per year, where the average load (variable) does not exceed 70% of the standby power rating. No overload is available.

Standard Reference Conditions: air temperature 25°C (77°F), barometric pressure 99kPa, [110m (361ft) altitude], 30% relative humidity.

Note: The above ratings may be subject to derate at different operating conditions. Please see the Derate Guidelines on the Broadcrown Website.All power ratings and reference conditions in accordance with ISO 8528-1 and ISO 3046-1.

 

Key Features:

● Efficient water cooled diesel engine.

● Single bearing CGT Stamford alternator

● Radiator with pressure cap and drain point

● Fully guarded engine-driven fan

● Fully welded steel skid base with fork lift pockets

● Integral fuel tank with filler cap and gauge

● Heavy duty rubber anti-vibration mountings

● 12V starter battery and connecting cables

● Separate engine-driven battery charging alternator

● Spin on oil and fuel filters and dry type air filter element

● Industrial silencer (15dBA reduction) supplied loose

● Key Start control system with analogue instruments

● Main line circuit breaker

● Factory Test CertifiCAT-parts-partse

● Operation & Maintenance Manual

● Wide range of optional extra features available

 

3-Phase Single Bearing John Deere Diesel Generator , 3029DF128 1

 

3-Phase Single Bearing John Deere Diesel Generator , 3029DF128 23-Phase Single Bearing John Deere Diesel Generator , 3029DF128 3

 

3-Phase Single Bearing John Deere Diesel Generator , 3029DF128 4

 

STANDARD CONTROL SYSTEM

BC 7210 Digital Auto Start

The standard control system for this model is the BC 7210 Auto Start system, based on the DSE 7210 control module, which provides :

▪ Automatic remote start

▪ Overspeed protection

▪ Underspeed protection

▪ Low oil Pressure protection

High coolant temperature protection

▪ Fail to Start indiCAT-parts-partsion

▪ Automatic cool-down timer function

▪ Optional - Common Alarm & System In Auto volt-free contactsTogether with digital displays for :

▪ Volts, Amps and Frequency

▪ Engine operating hours

This system also has an increased digital input/output count for external options and, being cost effective in comparison with the optional (BC 701) analogue system, is the preferred choice for most customers.

3-Phase Single Bearing John Deere Diesel Generator , 3029DF128 5

 

CONTROL SYSTEM OPTIONS

BC 7310 & BC 7320 control systems (just the DSE modules shown here) provide complete power monitoring and protection facilities.Compared to BC 7210, addition features include :

▪ Pre-alarms for Low Oil Pressure and High Coolant Temperature

▪ Digital display of kW, kVA and Power Factor

▪ Under/Over Volts protection▪ Over Current Protection

▪ Full RS485 Telemetry implementation as well as full SAE J1939 CANBus implementation. In fact, all generating sets driven by engines with onboard ECU/CANBus come with this system as standard.

 

The BC 7320 provides full AMF functionality with integrated mains monitoringand generator/mains contactor control.

3-Phase Single Bearing John Deere Diesel Generator , 3029DF128 6

 

BC 8610 & BC 8620 control systems provide the same features asBC 7310 & BC 7320 respectively, plus :

▪ BC 8610 - Set-to-Set Synchronisation

▪ BC 8620 - Single Set-to-Mains Synchronisation with integrated mains monitoring

For Multi Set-to-Mains synchronisation, each set requires BC 8610 with the addition of one mains monitoring panel BC 8660 (not illustrated).See the Synchronisation Guidelines for further details.

 

3-Phase Single Bearing John Deere Diesel Generator , 3029DF128 7

 

The optional control system for this model is BC 701 (photo), based on the Deep Sea Electronics DSE701 Key Start controller.This provides for the manual control of the generator via a two-position key switch and membrane push button for Start, together with Overspeed, Low Oil Pressure and High Coolant Temperature protection.

▪ LED indiCAT-parts-partsions for protection operation & charge alternator fail

▪ Analogue voltmeter with 7-position selector switch

▪ Analogue ammeter with 4-position selector switch

▪ Analogue frequency meter

▪ Analogue gauges for Oil Pressure, Coolant Temp & Charge Amps

▪ Engine hours counter

▪ Emergency Stop button

▪ One auxiliary input for optional features

▪ Optional - analogue kW meter, Generator Running volt-free output

The panel is constructed in 1.5mm steel, powder coated to RAL9001 for a high quality, durable finish with side-hinged door.

 

3-Phase Single Bearing John Deere Diesel Generator , 3029DF128 8

 

OPTIONAL ACOUSTIC ENCLOSURE

The optional acoustic enclosure for this model is Canopy 1, suitable for operation in harsh outdoor environmments whilst providing excellent security and acoustic performance. All steel canopy components are pre-treated and polyester powder coated (to a typical thickness of70-80μm) in RAL9001 white and the baseframe is finished in RAL9005 black.


Acoustically, the canopy is designed to meet the requirements of EU Legislation 2000/14/EC, achieved by extensive use of fire-retardant polyurethane foam together with efficient management of cooling air. Exhaust noise is minimised by internally mounted high performance exhaust silencers.


A steel fuel tank with filler, gauge and accessory points, is integrated within the baseframe. Alernatively, a bund with separate fuel tank can be provided where this is required.


Other key features include :

- Gull-wing doors with gas struts for good service access

- Panel/breaker access door with viewing window

- Heavy duty locks on all doors for total security

- Weather cap on exhaust discharge

- Emergency Stop button reloCAT-parts-partsed to canopy exterior

- Lifting and holding down points

- Fork Lift pockets

- Optional single roof lifting point.

 

3-Phase Single Bearing John Deere Diesel Generator , 3029DF128 9

 

3-Phase Single Bearing John Deere Diesel Generator , 3029DF128 10

KEY OPTIONS (Open Set)

Engine & Cooling :

- Electronic governor

- Oil and coolants drains extended to edge of baseframe

- Manual lub oil drain pump- Coolant heater

- Medium duty air cleaner

- Exhaust manifold guards

 

Fuel System :

- Baseframe with integral bund and drop

-in fuel tank

- Fuel filter/separator

- Low fuel level switch (single point)

- Fuel level switch (four point)

- Manual fuel transfer pump

- Pumped/gravity fuel transfer system

 

Alternator :

 

- Anti-condensation heater

- Quadrature droop kit

- Alternative AVR

- Thermistor probes and controls

 

 

Exhaust System :

 

- Residential silencer

- Critical silencer

- Flange/connection kit


Please refer to Broadcrown Sales Department for full details of these and other options

 

 